Environmentally friendly
Capacity | 125 kg to 20 t |
---|---|
Standard Lift |
3 m |
Use | Lifting Up/Down, Traversing Left/Right |
Voltage | 220-230V (50/60Hz), 380-415V (50Hz), 380-440V (60Hz), 500V (50Hz, Pole Change for Dual Speed), 460V (60Hz for Specific Regions) |
Voltage | 220-230V (50/60Hz), 380-415V (50Hz), 380-440V (60Hz), 500V (50Hz, Pole Change for Dual Speed), 460V (60Hz for Specific Regions) |
---|---|
Control Voltage |
24V (110V for Specific Regions) |
Duty Rating | Single Speed - 60% ED (60 min.) |
Dual Speed - 40/20% ED (30/10 min.) | |
Classification | M4, M5, M6 (ISO); 1 Am, 2 m, 3 m (FEM); H4 (ASME) |
Motor Insulation | Class B for 220-230V (50/60Hz), 380-440V (60Hz) Class F for 380-415V (50Hz), 380-440V (60Hz) |
Enclosure | Hoist Body - IP55, Push Button Control - IP65 |
Operating Temperature |
-20 to 40℃ (-4 to 104℉) |
Operating Humidity | 85%RH or Less |
Specification of products may differ depending on your location.
Please contact KITO and KITO's global partners for more information.
Code | Capacity (t) |
Std. Lift (m) |
Lifting Motor |
Lifting Speed* (m/min) |
Flange Width B (mm) |
||
---|---|---|---|---|---|---|---|
50/60Hz | |||||||
Output (kW)) | High | Low | Standard | ||||
ER2SP001IH | 125kg | 3 | 0.56 | Preset | 16.6 | 2.8 | 50-102 |
Adjustable | 1.4 | ||||||
ER2SP005IS | 500kg | 0.9 | Preset | 8.5 | 1.4 | ||
Adjustable | 0.7 | ||||||
ER2SP010IS | 1 | 1.8 | Preset | 8.2 | 1.4 | 58-127 | |
Adjustable | 0.7 | ||||||
ER2SP020IS | 2 | 3.5 | Preset | 8.2 | 1.4 | 82-153 | |
Adjustable | 0.7 | ||||||
ER2SP030IS | 3 | Preset | 5.2 | 0.9 | |||
Adjustable | 0.4 |
*The high speed is preset to the maximum speed in KITO factory. The speeds are adjustable between High and Low.
Code | Headroom: C | D | a | b | e | m |
---|---|---|---|---|---|---|
ER2SP001IH | 395 | 470 |
204 |
182 | 46 | 47.5 |
ER2SP005IS | 415 | 530 | ||||
ER2SP010IS | 470 | 590 | 249 | 236 | 56 | 56 |
ER2SP020IS | 650 | 690 | 300 | 280 | 69 | 71 |
ER2SP030IS | 780 | 910 | 320 | 324 | 79 | 80 |
Code | Capacity (t) |
Std. Lift (m) |
Lifting Motor |
Lifting Speed (m/min) |
Flange Width B (mm) |
---|---|---|---|---|---|
Output (kW) |
50Hz | Standard | |||
ER2SP001HD | 125kg | 3 | 0.5/0.13 | 14.2/3.5 | 50-102 |
ER2SP005SD | 500kg | 0.9/0.23 | 7.1/1.8 | ||
ER2SP010SD | 1 | 1.8/0.45 | 7.2/1.7 | 58-127 | |
ER2SP020SD |
2 | 3.5/0.88 | 6.9/1.6 | 82-153 | |
ER2SP030SD | 3 | 4.4/1.0 |
Code | Headroom: C | D | a | b | e | m |
---|---|---|---|---|---|---|
ER2SP001HD | 395 | 470 | 204 | 182 | 46 | 47.5 |
ER2SP005SD | 415 | 530 | ||||
ER2SP010SD | 470 | 590 | 249 | 236 | 56 | 56 |
ER2SP020SD |
650 | 690 | 300 | 280 | 69 | 71 |
ER2SP030SD | 780 | 910 | 320 | 324 | 79 | 80 |
Code | Capacity (t) |
Std. Lift (m) |
Lifting Motor |
Lifting Speed (m/min) |
Flange Width B (mm) |
|
---|---|---|---|---|---|---|
Output (kW) |
50Hz | 60Hz | Standard | |||
ER2SP001H | 125kg | 3 | 0.56 | 14.1 | 16.9 | 50-102 |
ER2SP005S | 500kg | 0.9 | 7.3 | 8.8 | ||
ER2SP010S | 1 | 1.8 | 7.1 | 8.5 | 58-127 | |
ER2SP020S | 2 | 3.5 | 7.0 | 8.4 | 82-153 | |
ER2SP030S | 3 | 4.4 | 5.3 |
Code | Headroom: C | D | a | b | e | m |
---|---|---|---|---|---|---|
ER2SP001H | 415 | 490 | 204 | 182 | 46 | 47.5 |
ER2SP005S | 435 | 550 | ||||
ER2SP010S | 470 | 590 | 249 | 236 | 56 | 56 |
ER2SP020S | 650 | 690 | 300 | 280 | 69 | 71 |
ER2SP030S | 780 | 910 | 320 | 324 | 79 | 80 |
For additional security, an overload limiter (OLL) comes as a recommended option; preset to 115% of rated capacity. The OLL protects the hoist mechanism from damage under overload conditions. (The load can be lowered even after the OLL is triggered.) Adjustable setting: from 90-135% of rated capacity.
The KITO load bell accurately alerts you when your hoist is overloaded as a cost-effective means of enhancing the safety and efficiency of your operations.
Rated Capacity: 125 kg to 5 t (Inverter Only)
1) Upper/Lower Levels Easily Set with Push Button Switches
2) High Speed in No-load
Specification of products may differ depending on your location.
Please contact KITO and KITO's global partners for more information.